5.3
Moyenne
CVE-2022-25622 The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP…
Description
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
Produits et versions touchés
| Produit | Versions touchées | Corrigé en |
|---|---|---|
| SIMATIC CFU DIQ 2.0 | premières → < 2.0.0 | 2.0.0 |
| SIMATIC CFU PA 2.0 | premières → < 2.0.0 | 2.0.0 |
| SIMATIC ET 200AL IM 157-1 PN | Versions non publiées | |
| SIMATIC ET 200MP IM 155-5 PN HF 4.2 | 4.2.0 → dernières | Pas de correctif indiqué |
| SIMATIC ET 200pro IM 154-8 PN/DP CPU | Versions non publiées | |
| SIMATIC ET 200pro IM 154-8F PN/DP CPU | Versions non publiées | |
| SIMATIC ET 200pro IM 154-8FX PN/DP CPU | Versions non publiées | |
| SIMATIC ET 200S IM 151-8 PN/DP CPU | Versions non publiées | |
| SIMATIC ET 200S IM 151-8F PN/DP CPU | Versions non publiées |
Afficher les 67 autres branches Masquer les 67 autres branches
Références
- cert-portal.siemens.com cert-portal.siemens.com
- cert-portal.siemens.com cert-portal.siemens.com
Chronologie
- Publiée
- Dernière modification
Autres CVE de SIMATIC CFU DIQ
Les 5 CVE de SIMATIC CFU DIQ →
CVE-2025-40833
The affected devices contain a null pointer dereference vulnerability while processing specially crafted IPv4 requests
7.5
Élevée
CVE-2025-40820
Affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values…
7.5
Élevée
CVE-2024-23814
The integrated ICMP service of the network stack of affected devices can be forced to exhaust its available memory…
5.3
Moyenne
CVE-2020-28400
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service…
7.5
Élevée