CVE-2020-5953 A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI…

Description

A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2).

Affected products and versions

Product Affected versions Fixed in
n/a Versions not published
SIMATIC Field PG M5 22.01 earliest → < 22.01.10 22.01.10
SIMATIC Field PG M6 26.01 earliest → < 26.01.13 26.01.13
SIMATIC IPC127E 27.01 earliest → < 27.01.09 27.01.09
SIMATIC IPC227G 28.01 earliest → < 28.01.04 28.01.04
SIMATIC IPC277G 28.01 earliest → < 28.01.04 28.01.04
SIMATIC IPC277G PRO 28.01 earliest → < 28.01.04 28.01.04
SIMATIC IPC327G 28.01 earliest → < 28.01.04 28.01.04
SIMATIC IPC377G 28.01 earliest → < 28.01.04 28.01.04
Show the 9 other branches
Product Affected versions Fixed in
SIMATIC IPC427E 21.01 earliest → < 21.01.17 21.01.17
SIMATIC IPC477E 21.01 earliest → < 21.01.17 21.01.17
SIMATIC IPC477E PRO 21.01 earliest → < 21.01.17 21.01.17
SIMATIC IPC627E 25.02 earliest → < 25.02.12 25.02.12
SIMATIC IPC647E 25.02 earliest → < 25.02.12 25.02.12
SIMATIC IPC677E 25.02 earliest → < 25.02.12 25.02.12
SIMATIC IPC847E 25.02 earliest → < 25.02.12 25.02.12
SIMATIC ITP1000 23.01 earliest → < 23.01.10 23.01.10
SIPLUS IPC427E 21.01 earliest → < 21.01.17 21.01.17